TOA – NX300P – Network Audio Extender – Dual Channel
$5,499.00 RRP Inc GST
The TOA NX-300 is a network audio adapter that utilizes packet audio technology (*1). Connecting the NX-300 to a network (LAN or WAN) permits high-quality audio or contact control signals to be transmitted in real time. As existing networks can be used, systems can be constructed with no need for the installation of new wiring. Broadcasts using audio files and up to 8 different levels of priority control can also be made, and provided by stations, factories or other central facilities to individual bases. It can be mounted in an EIA equipment rack (1U size) with the use of an optional rack mounting bracket or installed on a wall using an optional wall mounting bracket. (*1) TOA’s unique technology which makes it possible to transmit high-quality audio signals in real time over an IP network. (*1) TOA’s unique technology which makes it possible to transmit high-quality audio signals in real time over an IP network.
The latest NX-300 firmware version is 2.0.1(update:2016/10/7).
The software version is 2.0.0(upload:2016/9/23).
Power Source | Supplied from an external 24V DC (21.6 – 26.4 V) power supply or AC adapter AD-246 (option) or the equivalent |
Power/Current Consumption | 10 W (AC operation), 310 mA (DC operation) |
Audio Input | 2 channels, balanced (transformer isolated)/unbalanced changeable, 2 k ohms, LINE/MIC changeable, volume adjustable Rated input: -20 dB(*1) (LINE)/-60 dB(*1) (MIC) PAD function (-16 dB(*1)), removable terminal block (6 pins) |
Audio Output | 2 channels, balanced (transformer isolated), 600 ohms or less Rated output: 0 dB(*1) (unbalanced input) /-2 dB(*1) (balanced input), removable terminal block (6 pins) |
Frequency Response | 50 Hz – 18 kHz (48 kHz sampling frequency, PCM, 0 to -6 dB deviation referred to 1 kHz) |
Distortion | 0.2 % or less (1 kHz, LINE signal level, at rated output) |
Signal to Noise Ratio | 73 dB or more (LINE signal level, at rated output) |
Separation | 70 dB or more (1 kHz, LINE signal level, BPF) |
Audio Format | WAV file |
Number of Storable Audio Files | Max. 8 |
Storable Time of Audio File | Max. 2 min. per audio fi le (16 kHz sampling frequency, sub-band-ADPCM, monaural operation) |
Control Input | 8 channels, no-voltage make contact input, Open voltage: 24V DC, short-circuit current: 2 mA or less, removable terminal block (9 pins) (Only Channel 8 equipped with failure detection.) |
Control Input Failure Detection Section | Connection resistance to make the function inactive: 20 kohms -/+ 5 % Connection resistance to make the function active: 10 kohms -/+ 5 % Connector cable: Twisted pair cable (shielded type is recommended) |
Control Output | 8 channels, open collector output (polarized), withstand voltage: 30V DC, control current: 50 mA max., removable terminal block(9 pins) 2 channels, relay output (non-polar), withstand voltage: 30V DC, control current: 500 mA max., removable terminal block(4 pins) |
Network Section | Network I/F: 10BASE-T/100BASE-TX, Full-duplex/half-duplex Auto-negotiation Network Protocol: TCP, UDF, ARP, HTTP, RTP, IGMP, FTP, NTP Audio packet transmission system: unicast (Up to 16 simultaneous transmissions), multicast (Up to 64 simultaneous transmissions) Connector: RJ45 connector Voice sampling frequency: 8 kHz, 16 kHz, 32 kHz, 48 kHz (controllable by the software) Qualifying bit number: 16 bits Voice encoding method: PCM, sub-band ADPCM (controllable by the software) Voice packet loss recovery: Silence insertion Audio delay time: Min. 20 ms |
Operation | 2 channels, Audio input level control (convertible to Audio output level control) |
Indicator | 2 channels, audio input, SIGNAL (green)/PEAK (red), 2 channels, audio output, SIGNAL (green) LNK/ACT (green), BUSY (green), STATUS (green), ERROR (yellow), RUN (green) |
Setting switch | Reset, grand lift changeable, audio input 2 channels PAD changeable, audio input 2 channels LINE/MIC changeable |
SD Section | For log storage (Max. 10000) Media: SD/SDHC card (Max. 32 GB) (*2) File system: FAT16. FAT32 *Use only SD memory cards rated at 100 mA current consumption or less *No SD card provided |
Installation Method | Rack, Desk, Surface mount |
Operating Temperature | -10°C to + 50°C (14 °F to 122 °F), (0°C to + 40°C (32 °F to 104 °F) when AC adapter is in use.) |
Operating Humidity | 90 % RH or less (no condensation) |
Finish | Pre-coated steel plate, black, 30% gloss |
Dimensions (W x H x D) | 210 x 44.3 x 258 mm (8.27” x 1.74” x 10.16”) |
Weight | 1.7 kg (3.75 lbs.) |
Accessory | Removable terminal block (3 pins) x 1, Removable terminal block (6 pins) x 2, Removable terminal block (9 pins) x 2, Removable terminal block (4 pins) x 1, Plastic foot x 4, Screw for fitting plastic foot x 4 |
Option | Rack mounting bracket: MB-15B-BK (for rack mounting one NX-300 unit), MB-15B-J (for rack mounting two NX-300 units) Wall mounting bracket: YC-850, AC adapter: AD-246 |