Ampetronic – CMR3 – Calibrated Measuring Receiver
$440.00 RRP Inc GST
The Ampetronic CMR3 calibrated hearing loop measuring receiver for audio analysers is designed for measuring the performance of audio induction loop systems. The audio output is within ±0.25 dB over the frequency range and where used with a suitable audio analyser such as the Minilyser from Neutrik Ltd, the frequency response and field distribution of the magnetic field from any audio induction loop system can be plotted.
400mA/m RMS | 0dBu audio output (0.775V) |
Field strength | Coil orientation vertical as indicated on unit |
50Hz to 8kHz | ±0.25dB |
30Hz and 14kHz | -3dB |
A-weighting filter | EN61672-1:2003 sound level meter (Switched) |
Output variation over battery life | <0.1dB |
Output variation due to loading | <0.1dB |
Output variation over temperature range | <0.25dB |
Overall gain variation | <0.5dB |
Output type | Active Balanced |
Load impedance | >600Ω |
Connector | 3.5mm stereo jack socket |
Battery | 2 x AA alkaline |
Battery life | Approximately 200 hours |
Battery condition | OK when LED illuminated |
Dimensions | 62 w x 26 d x 112 h (mm) |
Weight | 84g (excluding batteries) |
Temperature range | -10°C to +45°C |
3.5mm stereo plug to XLR plug adaptor cable supplied (1.5m length), audio cables for simple interfacing of audio devices to loop systems available separately.
NTI AppNote AFILS E UP32801-9 data sheet
Blustream - DAC13DB - Digital Audio Converter w/ Down Mixing
Blustream - HD11CTRL - HDMI In -line Controller IR, RS-232, CEC, S ignal Sens
Blustream - HDMI18G-1 - 1M HDMI Cable Precision 18 Range Copper
Blustream - EX40B-KIT - HDMI Ov er CAT Extender Kit 1080P Max 40M @ 1080P